ics-ot-overview
ICS / OT attack category — Modbus, BACnet, S7Comm, DNP3. Routing skill: fingerprint the industrial protocol by port + Wireshark dissector, then load the matching sub-skill. SAFETY-CRITICAL: always confirm written scope before any write/control class action.
packages/decepticon/decepticon/skills/standard/exploit/ics-ot/SKILL.md
Source commit df879550544d36b6b1e69062f05adae28537adf2
What was checked
- Matches the observed repository HEAD
- Yes
- Scanner rules are current
- No
- Repository scan complete
- No
- Skill scan complete
- No
- Observed behavior
- Not checked yet
- Last checked
- Nov 8, 2026
These are observations at the recorded commit, not a guarantee of safety. Review the source before running it.
Install this skill
Choose an agent in your Stack or copy a command below. Commands fetch the pinned commit and copy only this skill directory. Existing destinations are refused. Copying a command does not install anything.
An install command is unavailable: current rules, complete repository and skill scans, an eligible behavior level and a permitted license are required.
Repository context
- Repository stars (not skill ratings)
- 6,567
- Repository last updated
- Nov 7, 2026
- License
- Apache-2.0
Observed agent integration: No specific integration evidence. Standard SKILL.md installation does not imply verified compatibility.
- agent Repository topic
- ai Repository topic
- cybersecurity Repository topic
- hacking Repository topic
- langchain Repository topic
- langgraph Repository topic
- llm Repository topic
- generative-ai Repository topic
- pentesting Repository topic
- pentest Repository topic
- ics,-ot,-scada,-industrial Declared skill tag
- engineering Derived category
Files and excerpt
File metadata and permitted, redacted excerpts come from the recorded scan. Source links are pinned to that commit.
Read excerpt
# Industrial Control Systems / OT Category
This is a routing skill for industrial protocol engagements. Identify the protocol by port + wire format, then load the matching sub-skill.
## SAFETY FIRST
Writes to ICS/OT devices can move physical actuators — open valves, trip breakers, freeze pumps, override safety setpoints. **Confirm written scope authorization for any write/control class operation. Read-only enumeration is generally safe.** If unsure, default to read-only.
## Protocol routing
| Protocol | TCP/UDP Port | Sub-skill | Wire fingerprint |
|---|---|---|---|
| **Modbus TCP** | TCP 502 | `modbus` | MBAP header, function codes 1-127 |
| **BACnet/IP** | UDP 47808 | `bacnet` | APDU PDU types 0-15, Who-Is/I-Am |